ESAI Programming Model
DSP56364 24-Bit Digital Signal Processor Users Manual, Rev. 2
6-38 Freescale Semiconductor
6.3.6.14 SAISR Transmit Odd-Data Register Empty (TODE) - Bit 17
When set, TODE indicates that the enabled transmitter data registers became empty at the beginning of an
odd time slot. Odd time slots are all odd-numbered slots (1, 3, 5, etc.). Time slots are numbered from zero
to N-1, where N is the number of time slots in the frame. This flag is set when the contents of the transmit
data register of all the enabled transmitters are transferred to the transmit shift registers; it is also set for a
TSR disabled time slot period in network mode (as if data were being transmitted after the TSR was
written). When set, TODE indicates that data should be written to all the TX registers of the enabled
transmitters or to the time slot register (TSR). TODE is cleared when the DSP writes to all the transmit
data registers of the enabled transmitters, or when the DSP writes to the TSR to disable transmission of the
next time slot. If TIE is set, an ESAI transmit data interrupt request is issued when TODE is set. Hardware,
software, ESAI individual, and STOP reset clear TODE.