Freescale-semiconductor Target Interface MMDS0508 Manual de usuario Pagina 63

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 86
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 62
Appendix
MMDS Commands
A–63MMDS0508 Target Interface
of Term A to H. Without a mask, the ST command uses the unmasked value 0x1F for
the clips.
Each trigger clip line has three options:
H - High
L - Low
X - Don’t Care
The bits of the clips and mask words are:
Bit: Signal:
0 Group A- BRN
1 RED
2 ORG
3 YEL
4 GRN
6 LIR (active low)
;R: Trigger on a read bus cycle only.
;W: Trigger on a write bus cycle only.
;RW: Trigger on a read or write bus cycle.
;D: Disable trigger (set trigger value, but disable trigger).
LIR: Trigger on a specific value for LIR signal.
LIR=H triggers when LIR is high.
LIR=L triggers when LIR is low.
LIR=X triggers when LIR is high or low.
If either the address or the data value of this command is a range, the analyzer
interprets both values as ranges. For example, the analyzer interprets the command
STC 8 20..40 as STC 8.. 8 20..40; it interprets the command STC 8..9
20 as STC 8..9 20..20.
If the command lacks any R, W, or RW value, the trigger defaults to read/write.
You can set the LIR signal with the clips (bit 6) or the LIR option.
Freescale Semiconductor, Inc.
For More Information: www.freescale.com
Vista de pagina 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 85 86

Comentarios a estos manuales

Sin comentarios